Install a vLC using the Azure portal
The Arctic Wolf® Virtual Log Collector (vLC) is a virtualized log collector for syslog. You can use the vLC independently or with Arctic Wolf Sensors.
Note:
- These steps only apply if you have a plan other than a Cloud Solution Provider (CSP) plan. If you have a CSP plan, see Install a vLC using the Azure portal with a CSP plan.
- During connectivity tests, appliances may communicate with external IP addresses behind a cloud service that Arctic Wolf hosts.
These actions are required:
- Make sure you have the appropriate Arctic Wolf permissions to install the appliance. Contact your Concierge Security® Team (CST) at security@arcticwolf.com to identify who in your organization has these permissions.
- Add all necessary IP addresses, ports, and services to your allowlist for full appliance functionality.
Tip: To see the IP addresses that you must allowlist, sign in to the Arctic Wolf Unified Portal, click , and then view the IP addresses in the section for your product.
- If you rate-limit the appliance with Quality of Service (QoS), remove this for best performance.
- If your firewall provides SSL/TLS inspection, do not do this inspection on the appliance management IP address.
- If you use an application proxy or layer 7 filter on your firewall, allow outbound traffic for the appliance management IP address.
- Optional: Configure two vLCs in a high availability environment. For more information, see Configure two vLCs in a high availability Azure environment.
- Configure log forwarding. For more information, see Syslog forwarding.
Provide your Azure account information to Arctic Wolf
Create a vLC instance
Connect to the serial console
In the left navigation, click Serial console.
Configure the vLC
Use the serial console to configure the vLC. For more information on using the serial console, see Serial console.
Activate the vLC
Note: Only the user who configured the vLC can activate the vLC.